Home / Buying guides / 201 vs 304 stainless

201 vs 304 Stainless Hinges

The two grades look the same on the shelf and behave very differently five years in. Here is how to choose between them without over- or under-specifying — and how to verify you got what you paid for.

12 min read · By Alwin Pan, Overseas Business Director, Haoyue Metal

Grade selection is one of the most common places an order goes wrong. A buyer saves on material, the doors go into a humid or coastal site, and the rust appears after installation — when replacement costs many times the original saving. This guide explains the real difference, how to read the test data, and how to confirm the grade on an incoming shipment.

The difference

It is the nickel, not the shine

Both 201 and 304 are stainless steels, and both look bright when new. The difference is the alloy: 304 contains roughly 18% chromium and 8% nickel; 201 substitutes some of that nickel with manganese and nitrogen. The result is that 304 resists corrosion significantly better, especially in wet or salty air, while 201 is cheaper. The nickel is what you are paying for, not the polish.

Indicative comparison — the mill certificate governs the actual order.
Property201304
Alloy~16–18% Cr, low Ni, Mn + N substituted[1]~18% Cr, ~8% Ni[1]
Corrosion resistanceModerate — fine in dry interiorsHigh — suitable for wet and coastal sites
Salt spray (indicative)Rust often within tens of hours72 h or more with no marked change
FormingHigher strength, lower elongation — can crack in deep draws[2]Better ductility, easier deep drawing and bending[2]
CostLowerHigher
Typical useFurniture, interior doors, dry cabinetsBathrooms, kitchens, marine, wash-down

A useful technical measure is the pitting resistance equivalent number, PREN = %Cr + 3.3×%Mo + 16×%N. 304 sits around 18–20; 201 around 14–16. Each point matters in chloride environments such as coastal air[2]. What that means in practice: an uncoated 201 bracket near the sea can show visible rust within half a year to a year, while 304 commonly stays sound for several years.

By environment

Which one for your project

Dry interior

Bedroom furniture, office cabinets, interior doors. 201 is adequate and saves money with no practical loss of performance.

Wet or coastal

Bathrooms, laundries, sea-side properties, commercial kitchens. Specify 304 — the extra cost is small compared with replacing rusted hinges and the labour to do it.

Food or medical

Wash-down environments and equipment cleaned with chemicals. 304 is the usual minimum; some specifications call for 316. Confirm with your customer.

A common buying mistake is to treat the choice as either "always 304" or "cheapest possible". The right answer follows the environment. Price the whole life of the installed hinge, not just the purchase order — sanding, repainting, replacement parts and call-outs usually cost more than the material saving.

Test data

How to read a salt spray figure

Salt spray hours are often quoted as if they were a score. They are not comparable unless four things are stated: the standard (ASTM B117 and GB/T 2423.17 are common), the pass criterion (first rust, red rust, or no visible change), the sample state (bare, passivated or coated; flat coupon or finished part), and the environment behind the number[3]. A flat passivated coupon will always outperform a finished hinge with bends and welds.

What to ask for

The standard number, the criterion, the sample description and the test report — all four. If a supplier gives a bare "72-hour salt spray" claim and cannot say what was tested, treat it as an adjective rather than data.

Our own figures

Our hinges are tested to 72 hours of neutral salt spray. We state the standard and the criterion on request, and the test is run on the finished part rather than a polished coupon, because that is what the customer installs.

Verification

How to be sure you got the grade you paid for

Ask for the mill certificate, and ask whether the heat or lot number on it follows the order through production. We buy strip to the grade written on the drawing — SUS304, SUS201 or SPCC — keep the certificate and delivery note on file, and record the lot number so a finished hinge can be traced back to its strip. A supplier who cannot show this is asking you to take the grade on trust.

Verification methods, from quickest to most reliable.
MethodReliabilityWhat it can and cannot tell you
Marking / certificateHigh, first checkSUS304, A2-70, A4-80 etc. plus a mill certificate with heat number. Vague "stainless steel" needs questioning.[4]
MagnetLow, rough screen onlyBoth grades are weakly magnetic after forming; it cannot reliably separate 201 from 304. It is useful for spotting zinc alloy or plain iron.
Acid test liquidBroad screening onlySeparates the 200 and 300 series roughly, cannot name a grade, and its strong acid damages the passive layer — avoid on finished parts.[4]
Handheld XRFHigh, quantitativeReads chromium, nickel and manganese directly in seconds, non-destructively. The accepted method for incoming inspection of critical parts.[1]

For coastal, food or medical projects, combine all of it: approve the certificate, screen a sample, and use XRF or a third-party lab report on the delivered batch. Put the grade and the verification method into the purchase order so there is something to hold against.

Questions

Frequently asked questions

What is the difference between 201 and 304 stainless steel?

304 has about 18% chromium and 8% nickel. 201 replaces part of the nickel with manganese and nitrogen — cheaper, but less corrosion-resistant. In salt spray, 201 often rusts within tens of hours while 304 withstands 72 hours or more; 304 also forms and welds better.

Is 201 stainless steel good enough for kitchens?

For dry indoor furniture, yes. For bathrooms, coastal properties, commercial kitchens and wash-down areas, specify 304 — the saving is quickly lost to rust and replacement labour.

Can a magnet tell 201 from 304?

Only as a rough screen. Cold forming introduces magnetism in both grades, so the result is unreliable. Acid test liquids only separate the series broadly and can damage the passive layer. The mill certificate or XRF analysis is the proof.

How should I read a salt spray test figure?

Ask for the standard, the pass criterion, the sample state and whether humidity was included. A bare "72-hour" claim without those four things is an adjective, not data.

How can I verify the grade I ordered?

Ask for the mill certificate with heat/lot number tied to your order. For critical projects use handheld XRF on the finished part, or a third-party lab report. We keep certificates and lot numbers for every run.

Is 304 worth the extra cost for a hinge?

In a dry interior, no — 201 or plated steel does the job. In a wet, salty or chemically cleaned environment, one replacement visit usually costs more than the material difference across the order.

Sources

References & further reading

Technical figures here are cited to published sources. Our own material certificates and in-house test data are available on request for any production run.

  1. Lonnmeter, How XRF analysis simplifies 201 vs 304 identification — alloy composition, salt spray comparison and XRF verification.
  2. 顺企网, 304 和 201 到底差在哪 — PREN values, salt spray behaviour, formability and identification methods.
  3. 辉旺建材, 201/304/316 怎么分、盐雾测试怎么读 — how to read a salt spray figure and the limits of test liquids.
  4. 云熵科技, 采购结构件时如何判断不锈钢 304 和 201 — inspection hierarchy and service-life data.

Related guides